High Flow Rate Fisher Gas Regulator 1098-EGR For Corrosive Environments Oxygen Service

Ask Latest Price
Video Channel
Brand Name :Fisher
Model Number :1098-EGR
Place of Origin :Assembled in China
MOQ :6sets
Price :USD5800-28500Each One Set
Payment Terms :T/T
Supply Ability :200sets Every Month
Delivery Time :8-10weeks
Packaging Details :1set packed in one wooden case.
Name :Fisher Type 1098-EGR Pressure Reducing Regulators
End Connetion :DN 25, 50, 80, 100, 150, 200 x 150, 300 x 150
Inlet Pressure :400psi
Maximum Pilot Supply Pressure :600 psig / 41.4 bar
Flow Rate :185000m³/h
Usage :Reduce tank pressure
more
Contact Now

Add to Cart

Find Similar Videos
WCC Steel Material Pressure Fisher Gas Regulator Self Operated 627H Model 00:36
WCC Steel Material Pressure Fisher Gas Regulator Self Operated 627H Model
View Product Description

Emerson Fisher Type 1098-EGR Pressure Reducing Regulators

High Flow Rate Fisher Gas Regulator 1098-EGR Pressure Reducing Regulator

For Corrosive Environments And Oxygen Service

Fisher Type 1098-EGR pressure gas regulator provide economical and accurate pressure control in a wide variety of applications;

natural gas distribution systems; fuel gas supply to industrial boilers, furnaces, ovens, and mixers; and large commercial / industrial establishments such as shopping centers and schools. They are also used in plant air service and in liquid service.

Table 1. Outlet Pressure Ranges and Spring Selection

Outlet Pressure Range (PSI/BAR) Spring Part Number Spring Color
3 to 15(0,21 to 1,03)
3 to 20(0,21 to 1,38)
5 to 35(0,34 to 2,41)
30 to 60(2,07 to 4,14)
35 to 100(2,41 to 6,90)
80 to 150(5,52 to 10,3)
1D892327022
1D751527022
1D665927022
1D745527142
1E543627142
1P901327142
Red
Silver
Blue
Green
Yellow
Brown
1. All springs can be backed off to 0 psig (0 bar). For the highest capacity and most accurate control, use the lowest-range spring that can be adjusted to the required setpoint.
2. C Cannot be used in anhydrous ammonia (NH3) applications.

Features

Versatility

Body Side Connection

Easy Maintenance

UL Listed

Specifications

Body Size and End Connection Style

End: 1/2-inch NPT
Gauge Outlet: 1/4-inch NPT

Maximum Inlet Pressure
250psi /17.2Bar

Spring Range

5~35psig (0.34~2.41bar)

Pressure Registration
Internal

Temperature Capabilities
-20º to 150ºF / -29º to 66ºC

The Type 64R has an integral low-capacity relief valve. The valve stem seats against a drilled hole in the diaphragm plate.

If the reduced pressure should exceed the set pressure, the diaphragm lifts off the valve stem so that a limited amount of

excess pressure can flow into the spring case and bleed out through a screened vent.

Fisher 64 Series regulator is also available with a handwheel. An optional handwheel is available for panel mounting.

1. Use qualified personnel when installing, operating, and maintaining these regulators. Before installation inspect for damage.

Make sure there is not any foreign material in the regulator and all tubing and piping are clean and unobstructed.

2. If installing the regulator at an outside location, point the spring case vent in the downward direction to protect it from

getting plugged or from collecting moisture, corrosive chemicals, or other foreign materials. Spring case vent orientation

may be changed by rotating the spring case with respect to the regulator body.

3. Install the regulator so that flow is from the IN to OUT connection as marked on the regulator body.

4. To remotely vent the spring case, remove the screen, if present, and connect 1/4-inch NPT piping or tubing to the spring

case connection. The piping or tubing should vent the spring case to a safe location, have as few bends as possible, and

have a screened vent on its exhaust end that is weather resistant and always pointed in the downward direction.

5. Like most regulators, 64 Series regulators have outlet pressure ratings lower than inlet pressure ratings. Although types

with internal relief include limited downstream overpressure protection, all types may require additional relief protection for

some service conditions if the actual inlet pressure can exceed the regulator outlet pressure rating or the pressure ratings

of any downstream equipment. Inspect a regulator periodically and after any overpressure condition.

6. Each regulator is factory-set for the pressure setting specified on the order. If no setting is specified, outlet pressure is

factory-set at the midrange of the control spring.

High Flow Rate Fisher Gas Regulator 1098-EGR For Corrosive Environments Oxygen Service

Inquiry Cart 0
You May Like
Fisher 299H Flange End Fisher Control Gas Regulator Pressure Reducing Valve
Fisher 299H Flange End Fisher Control Gas Regulator Pressure Reducing Valve
Fisher CS400 2 Inch End Connection Fisher Regulator Valve CS400IN8EC8 Use On Gas Boiler
Fisher CS400 2 Inch End Connection Fisher Regulator Valve CS400IN8EC8 Use On Gas Boiler
1301F-1 Model Fisher Natural Gas Regulator 1/4 Inch End Connection Fisher Brass Body
1301F-1 Model Fisher Natural Gas Regulator 1/4 Inch End Connection Fisher Brass Body
Durable Fisher 657 And 667 Pneumatic Diaphragm Actuator For Control Valve
Durable Fisher 657 And 667 Pneumatic Diaphragm Actuator For Control Valve
Long Life American Fisher Gas Pressure Regulator For Fire & Gas Systems 299H
Long Life American Fisher Gas Pressure Regulator For Fire & Gas Systems 299H
Fisher R622H-DGJ 250 Psi Fisher Differential Pressure Regulator Optional Spring Range
Fisher R622H-DGJ 250 Psi Fisher Differential Pressure Regulator Optional Spring Range
Gas Heating Equipment Fisher Gas Regulator Two Stage Compact Design
Gas Heating Equipment Fisher Gas Regulator Two Stage Compact Design
Aluminum Fisher Gas Valve 2625 2625NS Volume Boosters Positioner Output
Aluminum Fisher Gas Valve 2625 2625NS Volume Boosters Positioner Output
Fisher Gas Valve 95 Model MR95HP Model Gas Regulator Flange End Regulator For Fired Heaters And Boilers
Fisher Gas Valve 95 Model MR95HP Model Gas Regulator Flange End Regulator For Fired Heaters And Boilers
Model 64-35 High Pressure LPG Fisher Gas Regulator 64 Pressure Reducing Valve
Model 64-35 High Pressure LPG Fisher Gas Regulator 64 Pressure Reducing Valve
Ductile Iron Fisher Gas Regulator 627 Model Pressure Gas Regulator 250PSI Inlet
Ductile Iron Fisher Gas Regulator 627 Model Pressure Gas Regulator 250PSI Inlet
1301F-3 Model Fisher Gas Pressure Regulator , Fisher Flow Control Valve
1301F-3 Model Fisher Gas Pressure Regulator , Fisher Flow Control Valve
Light Weight Fisher Pressure Control Valve High Capacity Protective Inlet Screen
Light Weight Fisher Pressure Control Valve High Capacity Protective Inlet Screen
R622-DFF LPG Fisher Gas Regulator For Welding And Cutting Industry
R622-DFF LPG Fisher Gas Regulator For Welding And Cutting Industry
10 Psi R622-DFG Fisher R622 Model Gas Regulator Emerson Low Pressure Lpg Regulator
10 Psi R622-DFG Fisher R622 Model Gas Regulator Emerson Low Pressure Lpg Regulator
Send your message to this supplier
*From:
*To:

Suzhou Ephood Automation Equipment Co., Ltd.

*Subject:
*Message:
Characters Remaining : (0/3000)
Contact Now